Access Control Wiring

What Type of Wire Is Used for Access Control?

There is no single wire for access control. Learn which cable suits card readers, RS-485 and OSDP, Ethernet, and lock power, and why gauge matters.

On this page
  1. The short answer
  2. Reader data cable
  3. Lock power wire
  4. Ordinary alarm cable
  5. Jacket rating and where the cable runs
  6. Practical checklist

The short answer

There is no single wire for access control. The right cable depends on the reader’s interface, the controller, the lock’s voltage and the length of the run. Use the cable the manufacturer specifies, and check the manual before you buy.

Reader data cable

For readers that send a data signal, the common choices are:

  • Wiegand. Many readers use a multi-conductor cable, often shielded. Maximum run lengths vary by manufacturer, and guides cite anywhere from a few hundred feet to about 150 meters, so check your reader’s documentation for the conductor count and the distance limit.
  • RS-485 with OSDP. This uses twisted pair. One reader specification calls for 24 AWG twisted pair with a characteristic impedance of 120 ohms. Maximum lengths vary widely by product, so confirm the figure in the manual.
  • Ethernet for IP readers. Use Cat5e or Cat6 cable. The Ethernet channel limit is 100 meters, about 328 feet, and power over Ethernet follows the same limit.

For card readers, a common recommendation is 22-gauge, six-conductor stranded shielded cable. Shielding helps reduce electrical noise. Stranded copper is more flexible than solid wire and handles movement better. Avoid copper-clad aluminum, which many manufacturers do not accept for these signals.

Lock power wire

Electric strikes and maglocks draw more current, and voltage drops over distance. If the lock is far from its power supply, a thin wire can leave the lock with too little voltage to release or hold reliably. For longer runs, a heavier gauge such as 18 AWG is a common choice, but the right size depends on the lock’s current draw and the distance. Measure the voltage at the lock while it is operating, not only at the supply.

Ordinary alarm cable

Low-voltage alarm cable is not automatically suitable for every access control signal. Some alarm wire is built for different signaling. Use the cable type the reader or controller manual calls for, rather than whatever is already on the spool.

Jacket rating and where the cable runs

Cable has to suit the space it passes through. Walls, ceilings and ducts can have different fire-performance rules. Local electrical code sets the jacket rating you need, and that applies even when the wire is low voltage.

Practical checklist

  • Read the reader and controller manual first.
  • Match the conductor count to the diagram you are following.
  • Use stranded copper, and shielded cable where the manual asks for it.
  • Give lock power its own run, with a gauge heavy enough for the distance.
  • Check the lock voltage under load, not only at rest.

A door access control system wiring diagram shows which conductor goes where, but it does not tell you which cable to buy. That depends on the reader. A key card door access system, for example, usually sets the data cable choice, while a magnetic lock connection diagram points you to the power run that matters most. A door code lock system with a keypad may need less data cable, but it still needs correct lock power.